This manual provides a comprehensive guide to installing, configuring, and operating the Micro Motion 2700 transmitter, ensuring safe and compliant use in industrial applications.

1.1 Overview of the Micro Motion 2700 Transmitter

Micro Motion 2700 Transmitter is a versatile device designed for accurate measurement of mass, volume, and density in industrial applications. It features a user-friendly display, multiple communication protocols, and is renowned for its reliability and adaptability to various industrial processes.

1.2 Key Features and Benefits

The Micro Motion 2700 offers precise mass, volume, and density measurements with advanced digital communication options. Its user-friendly interface and configurable I/O options enhance process-specific customization, ensuring optimal performance and integration in various industrial settings while maintaining compliance with safety standards.

1.3 Safety Precautions and Compliance

Adhere to safety guidelines to protect personnel and equipment. Ensure compliance with European directives and follow proper return procedures to maintain legal standards. Read all safety messages carefully before proceeding with any operation or maintenance task.

Installation and Mounting Guidelines

Mount the transmitter in integral or remote setups, ensuring proper alignment and wiring. Follow installation type indications for Model 2700 to guarantee accurate performance and compliance with safety standards.

2.1 Mounting Options for Integral and Remote Installations

The Micro Motion 2700 transmitter supports both integral and remote mounting configurations. Integral installations allow up to 360-degree transmitter rotation in 90-degree increments, while remote setups provide flexibility for various industrial environments, ensuring optimal installation based on specific application needs and space constraints for precise measurement and operation.

2.2 Sensor Wiring and Connection Requirements

Proper sensor wiring is critical for accurate operation. Ensure all connections comply with the manual’s guidelines, including voltage requirements and signal wiring for integral or remote setups. Verify wiring integrity to avoid measurement errors and ensure compliance with safety standards for reliable performance in industrial environments.

2.3 Installation Type Indication for Model 2700

Model 2700 installation types are indicated by the model number on the device tag. Integral installations allow 360° transmitter rotation in 90° increments, while remote installations require proper wiring and mounting. Verify installation type for correct setup and ensure compliance with safety and operational guidelines for optimal performance.

Configuration and Setup

This section guides you through powering up the transmitter, initial configuration, and adjusting digital communications settings to ensure proper startup and optimal performance.

3.1 Powering Up the Transmitter

Connect the power supply according to specifications, ensuring correct voltage and polarity. Turn on the transmitter and verify the display lights up. Allow the system to complete its self-test cycle. Check for any error messages and ensure all status indicators show normal operation before proceeding.

3.2 Initial Configuration and Startup Connection

Connect the transmitter using USB or serial cable and launch the configuration software. Select the appropriate communication protocol and baud rate. Perform a meter status check and verify all settings match your process requirements. Ensure the display shows correct measurements before proceeding to advanced configurations or adjustments.

3.3 Adjusting Digital Communications Settings

Select the desired communication protocol via the configuration software. Set baud rate, parity, and stop bits to match your system requirements. Use Emerson communication tools for advanced settings. Verify all adjustments ensure proper communication and data transmission accuracy for seamless integration with your industrial process control systems.

Operation and Measurement

The Micro Motion 2700 transmitter accurately measures mass, volume, and density in industrial applications. Its user-friendly display and configurable options ensure precise monitoring and control of processes.

4.1 Verifying Mass Flow Measurement

To verify mass flow measurement, check the transmitter’s display for accurate readings. Ensure proper zero adjustment and confirm the meter status. Follow the manual’s guidelines to validate measurements and ensure optimal performance in your industrial application;

4.2 Checking Meter Status and Zero Adjustment

Regularly check the meter status to ensure proper operation. Review safety messages and perform zero adjustment as outlined in the manual. This step is crucial for maintaining accuracy and reliability in mass flow measurements, ensuring optimal performance in industrial applications.

4.3 Understanding the User-Friendly Display

The Micro Motion 2700 features an intuitive display for real-time monitoring of mass flow, volume, and density measurements. Navigate through menus effortlessly to access configuration options, status updates, and diagnostic tools, ensuring seamless operation and troubleshooting for optimal performance in industrial settings.

Troubleshooting and Maintenance

This section covers common issues, solutions, and routine maintenance procedures for the Micro Motion 2700, ensuring optimal performance and longevity of the transmitter in industrial environments.

5.1 Common Issues and Solutions

Common issues include measurement inaccuracies, communication errors, and sensor malfunctions. Solutions involve verifying zero adjustments, checking wiring connections, and ensuring proper digital communication settings. Regular maintenance and calibration can prevent these issues, ensuring reliable operation and accuracy in industrial applications.

5.2 Routine Maintenance and Calibration

Regular maintenance involves checking electrical connections, verifying sensor accuracy, and ensuring proper installation. Calibration should follow predefined procedures to maintain precision. Always refer to the manual for specific steps and safety guidelines to ensure optimal performance and compliance with operational standards.

5.3 Returning Equipment to Micro Motion

Always follow Micro Motion’s return procedures to ensure compliance with legal and safety standards. Obtain proper authorization and use approved shipping methods. Equipment not returned according to guidelines will not be accepted, ensuring safety for personnel and adherence to regulatory requirements.

Communication Protocols and Integration

Micro Motion 2700 supports multiple communication protocols, including PROFIBUS-PA, ensuring seamless integration with industrial systems. Emerson communication tools enable efficient setup and customization for optimal performance in various process environments.

6;1 Supported Communication Protocols

The Micro Motion 2700 supports PROFIBUS-PA, HART, and other protocols, enabling integration with industrial systems. These protocols facilitate seamless communication, ensuring compatibility with Emerson tools and enhancing process control capabilities across diverse applications.

6.2 PROFIBUS-PA Segment Configuration

Proper configuration of the PROFIBUS-PA segment ensures reliable communication. Follow PROFIBUS-PA installation guidelines and use Emerson tools for setup. This ensures seamless integration with industrial systems, optimizing performance and data accuracy in process control applications.

6.3 Using Emerson Communication Tools

Emerson communication tools, such as AMS Suite, simplify configuration and troubleshooting of the Micro Motion 2700. These tools enhance device management, ensuring seamless integration with industrial systems and optimizing performance for precise measurement and control in various applications.

Technical Specifications and Ordering Information

Find detailed product specifications, part numbers, and compliance information for the Micro Motion 2700 transmitter, ensuring accurate ordering and installation tailored to your industrial application needs.

7.1 Product Specifications and Data Sheets

Access comprehensive technical details, including flow range, accuracy, and environmental ratings, in the product data sheets for the Micro Motion 2700 transmitter, ensuring informed decision-making for industrial applications.

7.2 Ordering Information for Model 2700

Find detailed part numbers, configurations, and availability for the Micro Motion 2700 transmitter. Specific models like 2700R11BBZPZZZ and 2700R17BBMEZZZ are listed, along with housing options and mounting types. Shipping times, such as 3-5 weeks, and base pricing are also provided for planning and procurement purposes.

7.3 Part Numbers and Availability

Part numbers like 2700R11BBZPZZZ and 2700R17BBMEZZZ are available, with details on housing types such as polyurethane-painted aluminum. Availability is typically 3-5 weeks, with a base price of $3,852.00. Ensure to reference the ordering information for specific configurations and shipping timelines.

Advanced Features and Customization

The Micro Motion 2700 offers advanced customization options, including configurable I/O settings and performance tuning for specific processes. Models like 2700R11BBZPZZZ are available with detailed specs.

8.1 Configurable Input/Output Options

The Micro Motion 2700 supports multiple I/O configurations, enabling seamless integration with various systems. Users can customize inputs and outputs to meet specific application needs, enhancing flexibility and performance in industrial environments. This feature ensures optimal data communication and process control.

8.2 Customizing Performance for Specific Processes

The Micro Motion 2700 transmitter offers advanced customization options to optimize performance for specific industrial processes. Users can tailor settings for precise measurement of mass flow, density, and volume, ensuring accuracy and reliability in diverse applications. This adaptability enhances operational efficiency and satisfies unique process requirements.

8.3 Application-Specific Configurations

The Micro Motion 2700 transmitter supports application-specific configurations, enabling precise measurement in diverse industrial settings. Users can adapt settings for custody transfer, high-accuracy metering, or unique process demands, leveraging Emerson’s tools and guidelines for tailored solutions that meet specific application requirements;

Safety Messages and Compliance

Safety messages are provided to protect personnel and equipment. Compliance with European directives is ensured through proper installation and legal procedures, as outlined in the manual.

9.1 Safety Guidelines for Personnel and Equipment

Adhere to all safety guidelines to protect personnel and equipment. Read safety messages carefully before proceeding. Ensure proper installation, use protective gear, and follow procedures to prevent hazards and maintain compliance with legal standards.

9.2 Compliance with European Directives

The Micro Motion 2700 ensures compliance with relevant European directives when installed and operated as per manual instructions. Proper installation guarantees adherence to legal standards, ensuring safe and compliant operation in European markets and regulatory environments.

9.3 Legal Compliance for Equipment Returns

Equipment returns must follow Micro Motion’s specified procedures to ensure legal compliance with transportation and environmental regulations. Failure to adhere to these procedures may result in non-acceptance of returned items, ensuring safety and regulatory alignment for both customers and Micro Motion operations.

Customer Support and Resources

Contact Micro Motion customer service at 800-522-MASS (US) or 1 303-527-5200 (Canada and Latin America). Visit www.emerson.com for product manuals, troubleshooting guides, and additional support resources.

10.1 Contacting Micro Motion Customer Service

For technical assistance, contact Micro Motion Customer Service at 800-522-MASS (800-522-6277) in the U.S. or 1 303-527-5200 in Canada and Latin America. Visit www.emerson.com for product manuals, troubleshooting guides, and additional resources to support your Micro Motion 2700 operations effectively.

10.2 Accessing Manuals and Product Documentation

Visit the Emerson website at www.emerson.com to access product data sheets, configuration manuals, and troubleshooting guides for the Micro Motion 2700. These resources provide detailed specifications, installation instructions, and maintenance tips to ensure optimal device performance and compliance with safety standards.

10.3 Additional Resources for Troubleshooting

For further troubleshooting support, visit Emerson’s website for access to FAQs, technical bulletins, and software tools like AMS Device Manager. Contact Micro Motion customer service for personalized assistance, or explore online forums for peer-reviewed solutions and expert advice.

Verify system performance, ensure accuracy, and adhere to best practices for optimal operation. Confirm all safety guidelines and configurations are met before final deployment.

11.1 Summary of Key Steps and Best Practices

Ensure proper installation, configuration, and calibration of the Micro Motion 2700. Follow safety guidelines, verify measurements, and perform routine maintenance. Utilize Emerson tools for troubleshooting and consult the manual for advanced configurations to optimize performance and accuracy in industrial applications.

11.2 Final Verification of System Performance

After setup, verify the Micro Motion 2700’s performance by checking mass flow accuracy, communication settings, and display functionality. Ensure all configurations align with process requirements and consult the manual for troubleshooting any discrepancies to guarantee optimal operation.

11.3 Ensuring Optimal Operation and Accuracy

Regularly verify settings, connections, and calibration to maintain precision. Refer to the manual for detailed procedures and utilize Emerson communication tools for advanced adjustments. Ensure compliance with safety guidelines to guarantee optimal performance and consistent measurement accuracy across all applications.

Leave a Reply